Object Explorer Error on both boxes

Giganews Newsgroups
Subject: Object Explorer Error on both boxes
Posted by:  Offeral (Offer…@discussions.microsoft.com)
Date: Tue, 22 Jan 2008

I've researched a lot about the namespace error that some people get when
connecting to a cluster with Object Explorer from SSMS, however, no answer is
generally proposed that encompasses my particular situation.  We have a two
node failover cluster that we recently upgraded to 2005.  Any time someone
connects the Object Browser to our virtual server, we get the ole

Event filter with query "select * from __InstanceModificationEvent within 10
where TargetInstance isa 'Win32_Service'" could not be (re)activated in
namespace "//./root/Microsoft/SqlServer/ComputerManagement" because of error
0x80041010. Events may not be delivered through this filter until the problem
is corrected.

All my research has been that this would be addressed in SP2.  Well we're on
version 9.00.3042.00, meaning we've already got SP2 on our cluster.  I was
wondering if anyone has any insight into what may be causing this issue.

Thanks in advance,
O.

Replies